Long-term power quality measurements in medium voltage networks

dc.contributor.affiliationLuleå University of Technology
dc.contributor.affiliationUniversity of Cordoba
dc.contributor.affiliationUniversity of Cordoba
dc.contributor.affiliationSkellefteå Kraft Elnät
dc.contributor.affiliationSkellefteå Kraft Elnät
dc.contributor.authorRönnberg, Sarah
dc.contributor.authorGutiérrez Ballesteros, Elena
dc.contributor.authorGil de Castro, Aurora
dc.contributor.authorWestman, Mailn
dc.contributor.authorBrodin, Magnus
dc.contributor.countrySweden
dc.contributor.countrySpain
dc.contributor.countrySpain
dc.contributor.countrySweden
dc.contributor.countrySweden
dc.contributor.detailedauthorRönnberg, Sarah , Luleå University of Technology, Sweden
dc.contributor.detailedauthorGutiérrez Ballesteros, Elena, University of Cordoba, Spain
dc.contributor.detailedauthorGil de Castro, Aurora, University of Cordoba, Spain
dc.contributor.detailedauthorWestman, Mailn, Skellefteå Kraft Elnät, Sweden
dc.contributor.detailedauthorBrodin, Magnus, Skellefteå Kraft Elnät, Sweden
dc.date.accessioned2019-07-24T12:37:14Z
dc.date.available2019-07-24T12:37:14Z
dc.date.conferencedate3-6 June 2019
dc.date.issued2019-06-03
dc.description.abstractA power quality survey has been performed in several Swedish medium voltage (MV) substations and a study of the long-term power quality levels under normal operation has been done. The measurements have been performed during several years and the study includes seasonal variations as well as weekly and daily variations. This paper will focus on harmonic voltage distortion (THD and individual harmonics). An analysis has been done looking into metrological data to see any possible correlation with variations in harmonic distortion. Conclusions show that there are some significant differences over the years and between days for all sites. Long term measurements are needed to gain information on which levels one can expect, measuring for only a few weeks or month can give an over or underestimation of the actual levels. Results also shows that the magnitudes of harmonic distortion are well below the permitted level at all time at the selected sites.
dc.description.conferencelocationMadrid, Spain
dc.description.conferencenameCIRED 2019
dc.description.openaccessYes
dc.description.peerreviewedYes
dc.description.sessionPower quality and electromagnetic compatibility
dc.description.sessionidSession 2
dc.identifier.isbn978-2-9602415-0-1
dc.identifier.issn2032-9644
dc.identifier.urihttps://cired-repository.org/handle/20.500.12455/96
dc.identifier.urihttp://dx.doi.org/10.34890/197
dc.language.isoen
dc.publisherAIM
dc.relation.ispartProc. of the 25th International Conference on Electricity Distribution (CIRED 2019)
dc.relation.ispartofseriesCIRED Conference Proceedings
dc.titleLong-term power quality measurements in medium voltage networks
dc.title.number652
dc.typeConference Proceedings
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
CIRED 2019 - 652.pdf
Size:
1.42 MB
Format:
Adobe Portable Document Format