Comparative Study of Partial Discharge Localization based on UHF Detection Methods

dc.contributor.affiliationUniversity of New South Wales
dc.contributor.affiliationUniversity of New South Wales
dc.contributor.affiliationUniversity of New South Wales
dc.contributor.affiliationAmpcontrol
dc.contributor.authorChai, Hua
dc.contributor.authorLu, Shibo
dc.contributor.authorPhung, B. T.
dc.contributor.authorMitchell, Steve
dc.contributor.countryAustralia
dc.contributor.countryAustralia
dc.contributor.countryAustralia
dc.contributor.countryAustralia
dc.contributor.detailedauthorChai, Hua, University of New South Wales, Australia
dc.contributor.detailedauthorLu, Shibo, University of New South Wales, Australia
dc.contributor.detailedauthorPhung, B. T., University of New South Wales, Australia
dc.contributor.detailedauthorMitchell, Steve, Ampcontrol, Australia
dc.date.accessioned2019-07-24T12:38:50Z
dc.date.available2019-07-24T12:38:50Z
dc.date.conferencedate3-6 June 2019
dc.date.issued2019-06-03
dc.description.abstractPartial discharge (PD) monitoring is essential for insulation diagnostic of high voltage power transformers. PD activities can generate electromagnetic waves in the ultra-high frequency (UHF) range. The signals captured from several antennas installed inside the transformer can be analyzed to determine their time of arrival (TOA) and time difference of arrival (TDOA). Then by solving non-linear triangulation equations, the position of the PD source can be found for corrective action. This paper examines the effect of the sensor position on the S-parameter regarding the UHF sensor performance for PD detection. A comparative study of the methods in terms of PD localization based on the UHF method is then carried out. Acoustic, UHF and HFCT sensors are applied in the experiment. The results show that the transformer tank boundary can affect the sensor performance in capturing the signal and the acoustic-UHF triggering method has the highest level of accuracy.
dc.description.conferencelocationMadrid, Spain
dc.description.conferencenameCIRED 2019
dc.description.openaccessYes
dc.description.peerreviewedYes
dc.description.sessionOperation, control and protection
dc.description.sessionidSession 3
dc.identifier.isbn978-2-9602415-0-1
dc.identifier.issn2032-9644
dc.identifier.urihttps://cired-repository.org/handle/20.500.12455/278
dc.identifier.urihttp://dx.doi.org/10.34890/508
dc.language.isoen
dc.publisherAIM
dc.relation.ispartProc. of the 25th International Conference on Electricity Distribution (CIRED 2019)
dc.relation.ispartofseriesCIRED Conference Proceedings
dc.titleComparative Study of Partial Discharge Localization based on UHF Detection Methods
dc.title.number1076
dc.typeConference Proceedings
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
CIRED 2019 - 1076.pdf
Size:
734.65 KB
Format:
Adobe Portable Document Format