Modelling of harmonics produced by Compact Fluorescent Lamps in the frequency range 2-150 kHz

Loading...
Thumbnail Image

Paper number

1895

Working Group Number

Conference name

CIRED 2019

Conference date

3-6 June 2019

Conference location

Madrid, Spain

Peer-reviewed

Yes

Short title

Convener

Authors

Leroi, Caroline, Université Catholique de Louvain (UCL), Belgium
De Jaeger, Emmanuel, Université catholique de Louvain (UCLouvain), Belgium

Abstract

This paper studies the disturbances produced by a device made of a rectifier with an active power factor correction. In particular, it focuses on compact fluorescent lamps.  Active Power Factor Correction allows to reduce the low frequency harmonics (below 2 kHz) but it induces components at frequencies located in the frequency range 2-150 kHz. This paper presents the complete model of a compact fluorescent lamp and the design of its components. To reduce the simulation time, a simplified model made of a current source and the EMI filter is developed. A comparison of both models is performed and allows us to validate this simplified model.  

Table of content

Keywords

Publisher

AIM

Date

2019-06-03

Permanent link to this record

https://cired-repository.org/handle/20.500.12455/634
http://dx.doi.org/10.34890/858

ISSN

2032-9644

ISBN