Influence of PV plant 1 MWp connected on MV overhead line on voltage quality in PCC – case study

dc.contributor.affiliationP.U Elektroprivreda HZ HB- Mostar
dc.contributor.affiliationP.U Elektroprivreda HZ HB Mostar
dc.contributor.authorBago, Drago
dc.contributor.authorRamljak, Ivan
dc.contributor.countryBosnia and Herzegovina
dc.contributor.countryBosnia and Herzegovina
dc.contributor.detailedauthorBago, Drago, P.U Elektroprivreda HZ HB- Mostar , Bosnia and Herzegovina
dc.contributor.detailedauthorRamljak, Ivan, P.U Elektroprivreda HZ HB Mostar , Bosnia and Herzegovina
dc.date.accessioned2019-07-24T12:37:05Z
dc.date.available2019-07-24T12:37:05Z
dc.date.conferencedate3-6 June 2019
dc.date.issued2019-06-03
dc.description.abstractThis paper analyses influence of PV plant with great power on MV grid rated voltage 10 kV, considering voltage quality parameters. PV plant is connected on MV overhead line feeding rural customers (ACSR conductors). Point of common coupling (PCC) has relatively low value (weak grid). According to EN 50160:2011, measurement is performed in PCC point. Analysis and comparison of results before and after PV plant connection is performed. These measurements are necessity, so that potentially negative influence of PV plant on distribution grid can be seen. Obtain results of voltage quality parameters are compared with EN 50160:2011 limit values. Further, general impact of PV plant on distribution grid in PCC was analysed. Specificity of this paper is that analyzed PV plant is with great power and connected on MV weak grid. This PV plant is one of only few connected on MV grid in Bosnia and Herzegovina.
dc.description.conferencelocationMadrid, Spain
dc.description.conferencenameCIRED 2019
dc.description.openaccessYes
dc.description.peerreviewedYes
dc.description.sessionPower quality and electromagnetic compatibility
dc.description.sessionidSession 2
dc.identifier.isbn978-2-9602415-0-1
dc.identifier.issn2032-9644
dc.identifier.urihttps://cired-repository.org/handle/20.500.12455/67
dc.identifier.urihttp://dx.doi.org/10.34890/137
dc.language.isoen
dc.publisherAIM
dc.relation.ispartProc. of the 25th International Conference on Electricity Distribution (CIRED 2019)
dc.relation.ispartofseriesCIRED Conference Proceedings
dc.titleInfluence of PV plant 1 MWp connected on MV overhead line on voltage quality in PCC – case study
dc.title.number562
dc.typeConference Proceedings
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
CIRED 2019 - 562.pdf
Size:
581.92 KB
Format:
Adobe Portable Document Format