Fast recovery adaptable transformer for renewable generation

dc.contributor.affiliationABB
dc.contributor.affiliationABB
dc.contributor.affiliationIBERDROLA Renovables
dc.contributor.affiliationIBERDROLA Renovables
dc.contributor.affiliationIBERDROLA Renovables
dc.contributor.authorPacheco, Pablo
dc.contributor.authorCuesto, Miguel
dc.contributor.authorCAMPOS, Ignacio
dc.contributor.authorHERNÁNDEZ , Oscar
dc.contributor.authorMARCOS, Jesús
dc.contributor.countrySpain
dc.contributor.countrySpain
dc.contributor.countrySpain
dc.contributor.countrySpain
dc.contributor.countrySpain
dc.contributor.detailedauthorPacheco, Pablo, ABB, Spain
dc.contributor.detailedauthorCuesto, Miguel, ABB, Spain
dc.contributor.detailedauthorCAMPOS, Ignacio, IBERDROLA Renovables, Spain
dc.contributor.detailedauthorHERNÁNDEZ , Oscar, IBERDROLA Renovables, Spain
dc.contributor.detailedauthorMARCOS, Jesús , IBERDROLA Renovables, Spain
dc.date.accessioned2019-07-24T12:48:01Z
dc.date.available2019-07-24T12:48:01Z
dc.date.conferencedate3-6 June 2019
dc.date.issued2019-06-03
dc.description.abstractNowadays, distribution companies are requested to prepare detailed contingency plans, to efficiently manage temporary grid unavailability in case of a transformer failure. The main strategy to meet these challenges is to use adaptable recovery transformers with regards to compact, fast recovery and multi-voltage solutions — showing proven reliability under most demanding emergency conditions. This is the latest trend today after some years of development in materials, OEMs design rules and close collaboration with end users.The use of fast recovery adaptable transformers can significantly reduce reaction time — i.e., a compact single phase unit can be shipped and put into operation in just a few days. It would take weeks or even months to mobilize a large spare standard three phase transformer. The use of the right transformer technology, together with the use of high temperature material (as per IEC 60076-14), will allow to obtain reduced dimensions for such shipping activities. In this particular paper, a real case for a recovery shell-form adaptable transformer for renewable generation, having semi-hybrid insulation system, will be discussed. Both, compact shell and core form technologies are used for fast recovery applications. Selection of a design depends on the particular application, transportation limits and existing substation space limitations.
dc.description.conferencelocationMadrid, Spain
dc.description.conferencenameCIRED 2019
dc.description.openaccessYes
dc.description.peerreviewedYes
dc.description.sessionNetwork components
dc.description.sessionidSession 1
dc.identifier.isbn978-2-9602415-0-1
dc.identifier.issn2032-9644
dc.identifier.urihttps://cired-repository.org/handle/20.500.12455/710
dc.identifier.urihttp://dx.doi.org/10.34890/932
dc.language.isoen
dc.publisherAIM
dc.relation.ispartProc. of the 25th International Conference on Electricity Distribution (CIRED 2019)
dc.relation.ispartofseriesCIRED Conference Proceedings
dc.titleFast recovery adaptable transformer for renewable generation
dc.title.number2053
dc.typeConference Proceedings
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
CIRED 2019 - 2053.pdf
Size:
446.63 KB
Format:
Adobe Portable Document Format