Redundancy and Synchronization Improvement for Prevailing Phase Angle Estimation and Flicker Source location

dc.contributor.affiliationZIV Automation
dc.contributor.affiliationZIV Automation
dc.contributor.affiliationZIV Automation
dc.contributor.affiliationZIV Automation
dc.contributor.authorSantos, Sergio
dc.contributor.authorAmezua, Aitor
dc.contributor.authorPikula, Maja
dc.contributor.authorLlano, Asier
dc.contributor.countrySpain
dc.contributor.countrySpain
dc.contributor.countrySpain
dc.contributor.countrySpain
dc.contributor.detailedauthorSantos, Sergio, ZIV Automation, Spain
dc.contributor.detailedauthorAmezua, Aitor, ZIV Automation, Spain
dc.contributor.detailedauthorPikula, Maja, ZIV Automation, Spain
dc.contributor.detailedauthorLlano, Asier, ZIV Automation, Spain
dc.date.accessioned2019-12-19T18:19:59Z
dc.date.available2019-12-19T18:19:59Z
dc.date.conferencedate7 - 8 June 2018
dc.date.issued2018-06-07
dc.description.abstractThe deployment of renewable energy sources increases fluctuating power infeed of harmonics, flicker and unbalance caused by inverters and non-linear loads. The complexity of the power structure requires the measurement of voltage and current not only from the classical point of connection between customer and supplier. Time-varying harmonics require statistical post processing and depends on the observation of different voltage and currents. This paper proposes a model that provides redundancy of the measurement aggregated harmonic phasors not only at the Point of Common Connection, but in all the distribution feeders, with joint synchronous devices. This can be get with no additional expenditures than the required for the regular Low Voltage (LV) distribution monitoring.
dc.description.conferencelocationLjubljana, Slovenia
dc.description.conferencenameCIRED 2018 Ljubljana Workshop
dc.description.openaccessYes
dc.description.peerreviewedYes
dc.description.sessionNetwork integration, control concepts and operations
dc.description.sessionid3
dc.identifier.isbn978-2-9602415-1-8
dc.identifier.issn2032-9628
dc.identifier.urihttps://www.cired-repository.org/handle/20.500.12455/1091
dc.identifier.urihttp://dx.doi.org/10.34890/85
dc.language.isoen
dc.publisherAIM
dc.relation.ispartProc. of CIRED 2018 Ljubljana Workshop
dc.relation.ispartofseriesCIRED Workshop Proceedings
dc.titleRedundancy and Synchronization Improvement for Prevailing Phase Angle Estimation and Flicker Source location
dc.title.number0360
dc.typeConference Proceedings
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
CIRED 2018 Ljubljana WS - 0360 - 20848.pdf
Size:
316.81 KB
Format:
Adobe Portable Document Format