Response of Rotor Over-Voltage in DFIG Based Wind Generator under Recurring Voltage Sags

dc.contributor.affiliationSichuan University
dc.contributor.affiliationSichuan University
dc.contributor.affiliationCollege of Electrical Engineering and Information Technology Sichuan University
dc.contributor.affiliationSichuan University
dc.contributor.authorRen, Jie
dc.contributor.authorWang, Yang
dc.contributor.authorXiao, Xianyong
dc.contributor.authorLiu, Kai
dc.contributor.countryChina
dc.contributor.countryChina
dc.contributor.countryChina
dc.contributor.countryChina
dc.contributor.detailedauthorRen, Jie, Sichuan University, China
dc.contributor.detailedauthorWang, Yang, Sichuan University, China
dc.contributor.detailedauthorXiao, Xianyong, College of Electrical Engineering and Information Technology Sichuan University, China
dc.contributor.detailedauthorLiu, Kai, Sichuan University, China
dc.date.accessioned2019-07-24T12:38:12Z
dc.date.available2019-07-24T12:38:12Z
dc.date.conferencedate3-6 June 2019
dc.date.issued2019-06-03
dc.description.abstractThe automatic reclosing device may cause recurring voltage sags at grid connection point (GCP) of wind farm. In order to improve the low voltage ride through (LVRT) capability of DFIG based wind generator under recurring grid faults, this paper investigates the response of rotor over-voltage in DFIG based wind Generator. The study considered impacts of voltage magnitude, phase-angle jump (PAJ) and point-on-wave (POW) of single voltage sag event. And the effects of sag duration and the time interval between two adjacent sag on the DFIG flux and voltage are emphatically studied. The superposition and attenuation mechanism of stator flux and rotor over voltage of DFIG is analysed with related simulation.
dc.description.conferencelocationMadrid, Spain
dc.description.conferencenameCIRED 2019
dc.description.openaccessYes
dc.description.peerreviewedYes
dc.description.sessionPower quality and electromagnetic compatibility
dc.description.sessionidSession 2
dc.identifier.isbn978-2-9602415-0-1
dc.identifier.issn2032-9644
dc.identifier.urihttps://cired-repository.org/handle/20.500.12455/219
dc.identifier.urihttp://dx.doi.org/10.34890/426
dc.language.isoen
dc.publisherAIM
dc.relation.ispartProc. of the 25th International Conference on Electricity Distribution (CIRED 2019)
dc.relation.ispartofseriesCIRED Conference Proceedings
dc.titleResponse of Rotor Over-Voltage in DFIG Based Wind Generator under Recurring Voltage Sags
dc.title.number959
dc.typeConference Proceedings
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
CIRED 2019 - 959.pdf
Size:
1.43 MB
Format:
Adobe Portable Document Format