Comparative research between XLPE and P-laser MV-cable

dc.contributor.affiliationEnexis Netbeheer
dc.contributor.affiliationEnexis Netbeheer
dc.contributor.affiliationENGIE-Laborelec
dc.contributor.affiliationENGIE-Laborelec
dc.contributor.affiliationPrysmian Netherlands
dc.contributor.affiliationPrysmian Netherlands
dc.contributor.affiliationPrysmian Netherlands
dc.contributor.authorSoepboer, Piet
dc.contributor.authorBroersma, Tjeerd
dc.contributor.authorHennuy, Blandine
dc.contributor.authorSimal, Robin
dc.contributor.authorvan Rossum, Jos
dc.contributor.authorLauwers, Sander
dc.contributor.authorBartholomeus, Robert
dc.contributor.countryNetherlands
dc.contributor.countryNetherlands
dc.contributor.countryBelgium
dc.contributor.countryBelgium
dc.contributor.countryNetherlands
dc.contributor.countryNetherlands
dc.contributor.countryNetherlands
dc.contributor.detailedauthorSoepboer, Piet, Enexis Netbeheer, Netherlands
dc.contributor.detailedauthorBroersma, Tjeerd, Enexis Netbeheer, Netherlands
dc.contributor.detailedauthorHennuy, Blandine, ENGIE-Laborelec, Belgium
dc.contributor.detailedauthorSimal, Robin, ENGIE-Laborelec, Belgium
dc.contributor.detailedauthorvan Rossum, Jos, Prysmian Netherlands, Netherlands
dc.contributor.detailedauthorLauwers, Sander, Prysmian Netherlands, Netherlands
dc.contributor.detailedauthorBartholomeus, Robert, Prysmian Netherlands, Netherlands
dc.date.accessioned2019-07-24T12:42:13Z
dc.date.available2019-07-24T12:42:13Z
dc.date.conferencedate3-6 June 2019
dc.date.issued2019-06-03
dc.description.abstractCable manufacturer Prysmian developed a new insulation material for MV-cables called “P-laser” which is based on PP instead of PE. The recent cable tender of DSO Enexis Netbeheer in 2016 was partially awarded to Prysmian with the possibility to purchase this new P-laser cable. The advantages of P-laser is its recyclability and lower CO2-emissions during production. Enexis however learned from its purchase of the 1st generation XLPE cables in the ‘70’s. Therefore, a research project was set up in co-operation with ENGIE-Laborelec and Prysmian n order to investigate the behavior of a 1x630Al P-laser 6/10kV MV-cable in comparison with an identical cable with XLPE-insulation. Based on an analysis of how MV-cables are installed and operated in the network of Enexis, the following tests were performed:1. Verification with standard HD 620-10J and setting reference values for the comparison.2. Ampacity test (comparison of cable load and temperatures of XLPE and P-laser).3. Overbending test (behavior under a too small bend radius at -15 °, 90 ° and 110 ° C).4. Short-circuit test (short-circuit behavior up to 250 °C on the minimum permissible bend radius).Based on the recyclability of P-laser cable and the results of this comparative research, Enexis has decided to standardize P-laser insulated cable for utilization in its MV-network next to the already existing standard XLPE-cable.
dc.description.conferencelocationMadrid, Spain
dc.description.conferencenameCIRED 2019
dc.description.openaccessYes
dc.description.peerreviewedYes
dc.description.sessionNetwork components
dc.description.sessionidSession 1
dc.identifier.isbn978-2-9602415-0-1
dc.identifier.issn2032-9644
dc.identifier.urihttps://cired-repository.org/handle/20.500.12455/481
dc.identifier.urihttp://dx.doi.org/10.34890/705
dc.language.isoen
dc.publisherAIM
dc.relation.ispartProc. of the 25th International Conference on Electricity Distribution (CIRED 2019)
dc.relation.ispartofseriesCIRED Conference Proceedings
dc.titleComparative research between XLPE and P-laser MV-cable
dc.title.number1606
dc.typeConference Proceedings
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
CIRED 2019 - 1606.pdf
Size:
327.21 KB
Format:
Adobe Portable Document Format