• Admin Login
    View Item 
    •   CIRED Repository Home
    • CIRED Proceedings
    • CIRED 2019 Conference
    • View Item
    •   CIRED Repository Home
    • CIRED Proceedings
    • CIRED 2019 Conference
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Experience on diagnosis of MV cable in wind farm

    Thumbnail
    View/Open
    CIRED 2019 - 1689.pdf (899.0Kb)
    Paper number
    1689
    Conference name
    CIRED 2019
    Conference date
    3-6 June 2019
    Conference location
    Madrid, Spain
    Peer-reviewed
    Yes
    Metadata
    Show full item record
    Authors
    Park, Dae-jin, LS Cable & Systems, Korea Republic of
    Lee, Chung-hwan, LS Cable & Systems, Korea Republic of
    Lee, Hyeon-seok, LS Cable & Systems, Korea Republic of
    Kwon, Jung-ji, LS Cable & Systems, Korea Republic of
    Choi, Jin-wook, LS Cable & Systems, Korea Republic of
    Nam, Seok-hyun, LS Cable & Systems, Korea Republic of
    Abstract
    This paper shows the diagnostic technology of cable system in the wind farm. We diagnose the 22.9kV MV cable system which had occurred breakdown at several times at low wind speed generation. First of all, partial discharge is measured using on-line PD measurement system and oscilloscope because insulation of cable system is vulnerable in PD signal. Power quality is measured using power analyser for checking the condition of cable system. Power quality can affect insulation performance by generating the over-heat and additional losses. Power fluctuation, power factor, voltage & current and waveform and current unbalances of each phase are checked for identifying the power quality. We measured the harmonics by 50th orders and analysed the THDs of voltage and current. Recently, harmonics in voltage and current are increased due to non-linear components and loads in the power system. Especially, wind power system among the renewable energy system makes much harmonics and steep signal like flicker from power electronic devices. These extremely high frequency signals are accelerating the degradation of insulation and reducing the life of cables than power frequency signal. Therefore harmonics measurements of voltage and current have conducted.
    Publisher
    AIM
    Date
    2019-06-03
    Published in
    • CIRED 2019 Conference
    Permanent link to this record
    https://cired-repository.org/handle/20.500.12455/523
    http://dx.doi.org/10.34890/749
    ISSN
    2032-9644
    ISBN
    978-2-9602415-0-1

    Browse

    All of CIRED RepositoryCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    Admin LoginRegister

    DSpace software copyright © 2002-2021  DuraSpace
    Contact Us | Send Feedback
    DSpace Express is a service operated by 
    Atmire NV