Show simple item record

dc.contributor.authorcanova, aldo
dc.contributor.authorGiaccone, Luca
dc.contributor.authorCirimele, Vincenzo
dc.date.accessioned2019-07-24T12:38:59Z
dc.date.available2019-07-24T12:38:59Z
dc.date.issued2019-06-03
dc.identifier.isbn978-2-9602415-0-1
dc.identifier.issn2032-9644
dc.identifier.urihttps://cired-repository.org/handle/20.500.12455/290
dc.identifier.urihttp://dx.doi.org/10.34890/516
dc.description.abstractThe work presents a procedure to optimise a mixed passive and active shielding. The shielding concerns a building in proximity of a high voltage overhead line. This condition often arises in the reality. For Italian legislation, if the building is located at a distance that does not guarantee the respect of the limits on the magnetic flux density, the use of such building is not authorised for stays longer than 4 hours per day. In the case of overhead lines, the line operator can install a shielding acting directly on the source at the cost of difficult and expensive modifications to the pylons. The most feasible solution is to perform a shielding of the building which is generally passive and very rarely active. The selection of one or the other type of shielding is generally linked to factors external to the purely technical ones. This paper presents an optimised design of a shielding based on the use of both technologies. The search of the optimal condition has been based on performance parameters not considering cost constraints. The work presents two study cases characterized by different distances of the building that has to be protected from the power line.
dc.language.isoen
dc.publisherAIM
dc.relation.ispartofseriesCIRED Conference Proceedings
dc.titleActive and passive shield for aerial power lines
dc.typeConference Proceedings
dc.description.conferencelocationMadrid, Spain
dc.relation.ispartProc. of the 25th International Conference on Electricity Distribution (CIRED 2019)
dc.contributor.detailedauthorcanova, aldo, Politecnico di Torino, Italy
dc.contributor.detailedauthorGiaccone, Luca, Politecnico di Torino, Italy
dc.contributor.detailedauthorCirimele, Vincenzo, Politecnico di Torino, Italy
dc.date.conferencedate3-6 June 2019
dc.description.peerreviewedYes
dc.title.number1096
dc.description.openaccessYes
dc.contributor.countryItaly
dc.contributor.countryItaly
dc.contributor.countryItaly
dc.description.conferencenameCIRED 2019
dc.contributor.affiliationPolitecnico di Torino
dc.contributor.affiliationPolitecnico di Torino
dc.contributor.affiliationPolitecnico di Torino
dc.description.sessionPower quality and electromagnetic compatibility
dc.description.sessionidSession 2


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record