dc.description.abstractThe article describes the current experience in applying the diagnostics of MV cable lines in the DSO and the ongoing SORAL project. Diagnostic systems which measure partial discharges and tan delta in MV lines have been used in Poland since the turn of the century. Research work so far has focused on MV cables and on attempts to define key parameters which would indicate advanced ageing processes. However, key parameters indicating the increase in the failure risk have been identified. The research up to now is a valuable contribution to the process of creating assessment criteria for failure risk, using the IT system which automates this process. This task is carried out now in the SORAL project. Industrial research results will be the criteria for assessment of technical conditions of MV power line segments, based on technical and operational data and on diagnostic data obtained from measurements of partial discharges and tan delta. On the basis of decades-long experience in conducting diagnostic tests, and on the basis of technical and operational information gathered in GIS, the health index for specific elements of cable lines will be determined. As part of the development work, the IT system for assessment of the risk of failure of a MV power network will be built, based on assessment of technical conditions of specific elements of MV power lines. Health Index will be implemented in the SORAL system.
dc.language.isoen
dc.publisherAIM
dc.relation.ispartofseriesCIRED Conference Proceedings
dc.titleSORAL - System for condition monitoring and failure risk assessment of MV cable lines based of off line diagnostic methods
dc.typeConference Proceedings
dc.description.conferencelocationMadrid, Spain
dc.relation.ispartProc. of the 25th International Conference on Electricity Distribution (CIRED 2019)
dc.contributor.detailedauthorNoske, Slawomir, ENERGA-OPERATOR SA, Poland
dc.contributor.detailedauthorZasada-Chruscinska, Katarzyna, ENERGA-OPERATOR SA, Poland
dc.contributor.detailedauthorKolodziejczyk, Krzysztof, Globema sp. z o.o., Poland
dc.contributor.detailedauthorGrzelka, Sebastian, ENERGA-OPERATOR SA, Poland
dc.contributor.detailedauthorGrenda, Wojciech, Globema sp. z o.o., Poland
dc.date.conferencedate3-6 June 2019
dc.description.peerreviewedYes
dc.title.number1034
dc.description.openaccessYes
dc.contributor.countryPoland
dc.contributor.countryPoland
dc.contributor.countryPoland
dc.contributor.countryPoland
dc.contributor.countryPoland
dc.description.conferencenameCIRED 2019
dc.contributor.affiliationENERGA-OPERATOR SA
dc.contributor.affiliationENERGA-OPERATOR SA
dc.contributor.affiliationGlobema sp. z o.o.
dc.contributor.affiliationENERGA-OPERATOR SA
dc.contributor.affiliationGlobema sp. z o.o.
dc.description.sessionPlanning of power distribution systems
dc.description.sessionidSession 5


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record