Screen Connection for MV cables with laminatd Aluminium screen
Paper number
409Conference name
CIRED 2019Conference date
3-6 June 2019Conference location
Madrid, SpainPeer-reviewed
YesMetadata
Show full item recordAuthors
Bentkowski, Kai-Uwe, Behr Bircher Cellpack BBC Radeberg GmbH, GermanyHaim, Klaus-Dieter, University of Applied Sciences Zittau/Görlitz, Germany
Abstract
The medium voltage cable of the future will probably have an aluminium conductor and a laminated aluminium screen. The increasing use of conductor cross sections up to 1200 mm² leads to screen currents of much more than 100 A. This brings some problems for the grounding devices of such a cable. There is no international test standard for ground screen connecting devices. That’s why CIRED established the working group “CIRED WG 2017-1 Test Recommendation for Ground Screen Power Cable Connections”This paper gives an overview on possible screen currents and shoes test results of long-term tests with different grounding devices on cables with laminated aluminium screenPublisher
AIMDate
2019-06-03Published in
Permanent link to this record
https://cired-repository.org/handle/20.500.12455/17http://dx.doi.org/10.34890/38