Show simple item record

dc.contributor.authorKhokhlov, Victor
dc.contributor.authorMeyer, Jan
dc.contributor.authorSchegner, Peter
dc.contributor.authorAgudelo-Martínez, Daniel
dc.contributor.authorPavas, Andrés
dc.date.accessioned2019-07-24T12:37:31Z
dc.date.available2019-07-24T12:37:31Z
dc.date.issued2019-06-03
dc.identifier.isbn978-2-9602415-0-1
dc.identifier.issn2032-9644
dc.identifier.urihttps://cired-repository.org/handle/20.500.12455/142
dc.identifier.urihttp://dx.doi.org/10.34890/283
dc.description.abstractAdvances in power electronics, increasing share of renewables in the energy system and e-mobility cause an increase of disturbances in the frequency range from 2 to 150 kHz, also known as supraharmonics. This emission usually does not propagate very far, but can disturb other end user equipment, which can result in short-term effects (equipment malfunctions, audible noise or light flicker) as well as long-term effects (lifetime reduction due to additional thermal stress). This paper summarizes the results of a comprehensive immunity assessment of more than 50 household appliances with respect to the above mentioned disturbance effects. The results shall serve as a contribution to the ongoing standardization activities in the frequency range 2-150 kHz.
dc.language.isoen
dc.publisherAIM
dc.relation.ispartofseriesCIRED Conference Proceedings
dc.titleImmunity Assessment of Household Appliances in the Frequency Range from 2 to 150 kHz
dc.typeConference Proceedings
dc.description.conferencelocationMadrid, Spain
dc.relation.ispartProc. of the 25th International Conference on Electricity Distribution (CIRED 2019)
dc.contributor.detailedauthorKhokhlov, Victor, Technische Universitaet Dresden, Germany
dc.contributor.detailedauthorMeyer, Jan, Technische Universitaet Dresden, Germany
dc.contributor.detailedauthorSchegner, Peter, Technische Universitaet Dresden, Germany
dc.contributor.detailedauthorAgudelo-Martínez, Daniel, Universidad Nacional de Colombia, Colombia
dc.contributor.detailedauthorPavas, Andrés, Universidad Nacional de Colombia, Colombia
dc.date.conferencedate3-6 June 2019
dc.description.peerreviewedYes
dc.title.number763
dc.description.openaccessYes
dc.contributor.countryGermany
dc.contributor.countryGermany
dc.contributor.countryGermany
dc.contributor.countryColombia
dc.contributor.countryColombia
dc.description.conferencenameCIRED 2019
dc.contributor.affiliationTechnische Universitaet Dresden
dc.contributor.affiliationTechnische Universitaet Dresden
dc.contributor.affiliationTechnische Universitaet Dresden
dc.contributor.affiliationUniversidad Nacional de Colombia
dc.contributor.affiliationUniversidad Nacional de Colombia
dc.description.sessionPower quality and electromagnetic compatibility
dc.description.sessionidSession 2